4.1 The RM Solar M-Class Panel
The RM Solar M Class Panel has been specically designed to meet the needs of large
industrial applications. Suitable for both Commercial Buildings, and Private applications, such as
large swimming pool installations.
The M Class panels are also available as a horizontal variant allowing installation on roofs where
space is a premium.
The RM Solar M-Class panel is not intended to be used in drain-back systems.
Technical Information
Floor Space : 2.03 m2
Dimensions : 1010 x 2010 mm
Weight empty : 36.5 kg
Fluid Volume : 1.3 litres
Recommended ow of heat transfer uid : 30 L/h/m2 collector
Stagnation temperature : 170°C
Panel connection : in parallel
Maximum number of panels that can be linked : 10
Maximum number of series : Innate
Glazing : 4mm low iron hailstone resistant
Tested to EN 12975 (parts 1 & 2) and to Solar Rating & Certication Corporation Standards for the
United States of America and to all applicable Canadian test standards
Maintenance
The panels have been designed to withstand high temperatures; the glass does not require clean-
ing. There are no user serviceable parts inside and due to the heat exchange process the panel
does not contact potable water or water to be heated.